From Cancer Staging to Screening
Full-body magnetic resonance imaging (MRI) has come a long way from its early experimental roots to its current role as a powerful tool for cancer detection and surveillance. Today, with the inclusion of diffusion-weighted imaging with background body signal suppression (DWIBS), full-body MRI stands at the forefront of non-invasive imaging techniques, offering detailed insight into multiple organ systems without the use of ionising radiation.
Tesla’s Magnetic Revolution: The Foundation of MRI
A historical narrative of full-body MRI would be incomplete without acknowledging Nikola Tesla, who discovered the rotating magnetic field in the late 1880s (1). This foundational breakthrough in electromagnetism laid the groundwork for the physics that underpins modern MRI technology. In recognition of his contribution, the strength of magnetic fields is measured in tesla—a tribute to his groundbreaking work.
Translation from Bench to Humans
What we now know as “MRI” was previously called Nuclear Magnetic Resonance (NMR), with “nuclear” referencing the effect of the magnetic field on atomic nuclei, especially hydrogen molecules. NMR was first described in 1946 by Bloch and Purcell and was used as a research tool in chemistry and physics, which was later recognised by a Nobel Prize in Physics.
Decades later, several researchers laid the foundations of what would now be known as clinical MRI. In 1971, Damadian showed that NMR could differentiate between normal and cancerous tissues and began building the first human NMR (aka MRI) scanner, called “Indomitable.” Although clumsy and slow, Damadian successfully scanned the first human full-body in 1977.
Interestingly, another research group, Mansfield and Lauterbur, set out to complete scans in minutes rather than hours. The duo’s innovation led to a rapid imaging technique called “line-scan imaging” and spatial encoding, completing a finger scan in 15–20 minutes. Later, Mansfield and Lauterbur were awarded a Nobel Prize in 2003 for this innovation, without recognition of Damadian’s contribution—a decision that stirred considerable controversy within the industry (2).
Clinical Foundations: 1980s–1990s
As this novel imaging entered the commercial clinical space in the early 1980s, the term “MRI” was adopted for marketing purposes to avoid public concern around the word “nuclear” and its association with ionising radiation. In the mid-1980s, the FDA approved MRI scanners for clinical use, boasting field strengths of 0.15 to 0.5 Tesla, which would later be surpassed by the development of 1.5T platforms in the late 1980s.
Due to the superior soft tissue contrast offered, MRI rapidly replaced CT for the evaluation of neurological conditions including multiple sclerosis and brain tumours. However, despite the first full-body scan being performed in 1977, logistically feasible head-to-toe imaging remained a theoretical aspiration until the 1990s.
With the introduction of a moving scan table and improved scan times, full-body MRI began to find niche utility in certain oncology applications, particularly in detecting bone metastases from breast and prostate cancers by the late 1990s and early 2000s.
Adoption and Maturity: 2000–2020
The field of full-body imaging changed dramatically in 2004 when Dr. Takahara and colleagues introduced DWIBS (Diffusion-Weighted Imaging with Background Body Signal Suppression) (3). Developed for use on 1.5T MRI systems, DWIBS enabled radiologists to visualise malignancies throughout the body with high sensitivity, without relying on radioactive tracers. This innovation marked a turning point, elevating MRI from a regional diagnostic tool to a potential candidate for systemic cancer screening.
In parallel to Dr. Takahara’s innovation, other researchers developed “parallel-imaging” techniques (pun intended) (4). This, in addition to the adoption of 3T MRI platforms, laid the groundwork for modern high-speed MRI and continues to be used to offer faster scan times, improved patient comfort, and reduced motion artefacts.
Since the first report of full-body DWIBS, full-body MRI gained significant traction for oncological staging and treatment monitoring. Its utility was especially evident in paediatric cancers, as well as multiple myeloma, lymphoma, lung, colorectal, breast, and—more recently—prostate cancer, demonstrating excellent agreement with PET/CT (5–8). Medical consensus grew around its advantages, including high sensitivity, safety profile, and repeatability.
However, the transition to 3T MRI systems in the early to mid-2000s posed an unexpected challenge for full-body MRI. While these platforms are known for better resolutions and faster scan times, a new technical challenge surfaced: full-body DWIBS distortion and misalignment between imaging stations hindered uptake across 3T platforms (9).
As a result, the current literature is limited by heterogeneous imaging protocols, particularly the combination of studies using 1.5T systems with DWIBS and others using 3T systems without it. This inconsistency makes it difficult to draw meaningful conclusions about the overall sensitivity and diagnostic accuracy of full-body MRI.
A New Screening Tool
Full-body MRI first entered the cancer screening space as a tool for individuals with known hereditary cancer predisposition syndromes, most notably Li-Fraumeni syndrome, which involves mutations in the TP53 gene. In these high-risk populations, full-body MRI provided a radiation-free, whole-body surveillance method capable of identifying malignancies at an early, treatable stage—leading to improved survival outcomes (10).
As full-body MRI gained traction in high-risk populations, it was a natural progression to explore its potential in individuals without known genetic predispositions. The question soon followed: could full-body MRI serve as a reliable, multi-system cancer screening tool for the broader population?
In response, several companies in the United States and United Kingdom began offering commercial full-body MRI services. Early findings have demonstrated the modality’s ability to detect clinically significant cancers in otherwise asymptomatic individuals—highlighting its promise as a proactive, radiation-free health assessment tool.
While early concerns focused on the relatively high rate of incidental findings, including those of indeterminate nature (11), it’s important to recognise that these concerns are largely a reflection of technological constraints in image quality leading to poor lesion characterisation, rather than an inherent flaw in the concept of full-body MRI screening.
For example, the 2019 study by Kwee and Kwee synthesised findings from a broad range of full-body MRI research. However, the included studies showed considerable heterogeneity in imaging protocols. This included differences in scanner field strength—with both 1.5T and 3T systems represented—as well as variation in scan duration and sequence selection. Notably, none of the 3T studies (3/19 included studies) included the use of DWIBS for tissue characterisation, which may have significantly impacted the ability to detect and interpret lesions. This variability limits the reliability of conclusions regarding diagnostic sensitivity and overall accuracy.
This highlights that the core challenge is not simply in detecting abnormalities, but in accurately interpreting their significance and determining the most appropriate next steps for management.
Could standardised reporting, coupled with greater ability to characterise lesions, offer the clarity needed to minimise unwarranted anxiety and interventions?
Standardising Interpretation: The Introduction of ONCO-RADS
A key step in making full-body MRI suitable for broader use has been the development of structured reporting systems. Among these, the introduction of the ONCO-RADS (Oncologic Reporting and Data System) framework in 2021 aimed to guide radiologists in the consistent grading of lesions detected on full-body MRI, improving diagnostic clarity and aiding clinical decision-making (12).
Using a five-point Likert scale, findings on images are classified based on the likelihood of malignancy and offer standardised follow-up recommendations based on the individual’s known risk profile:
ONCO-RADS Table for whole-body MRI
| Category | Interpretation | Recommended Action |
| 1 | Definitely benign | No features suggest malignancy; no follow-up needed |
| 2 | Probably benign | Low likelihood of malignancy; routine follow-up or reassurance |
| 3 | Indeterminate | Equivocal; further imaging, risk stratification, or short-term follow-up |
| 4 | Probably malignant | Suspicious features present; further diagnostic work-up (e.g., biopsy) |
| 5 | Definitely malignant | Classic features of malignancy; urgent referral and definitive management |
Breakthrough at 3T: Inline Distortion Correction Full-body DWIBS
A significant milestone was reached in 2021 when Ben Kennedy, based at Mermaid Beach Radiology, successfully implemented the world’s first inline distortion-corrected full-body DWIBS on a 3T platform, including improved “background suppression” using modified radio-frequency pulses.
This achievement overcame key challenges associated with magnetic field-related image distortion, artefact, and station misalignment—leading to markedly improved anatomical accuracy and reproducibility.
This innovation forms the foundation of Whole Body MRI™’s exclusive imaging, and the advancement was recognised with a proffered paper award at an international ISMRM/ISMRT conference in 2022 (13).
In late 2024, the formal establishment of Whole Body MRI™ as a collaborative effort between Ben Kennedy and Dr. Zane Sherif marked a defining moment in the clinical application of this imaging modality.
Building upon years of technical refinement and clinical success, the pair have unified best practices, proprietary imaging protocols, and structured reporting tools into a comprehensive, standardised clinical product. It set the stage for broader adoption in preventive medicine and advanced screening, particularly for individuals seeking personalised, radiation-free imaging solutions.
Shift in Cancer Risk Profile
Despite the recent introduction of ONCO-RADS for structured reporting and the development of DWIBS distortion correction in Whole Body MRI™, a fundamental question remains:
Does full-body MRI screening improve long-term survival outcomes in individuals at low-to-average risk?
Anecdotally, we know there is improvement in health outcomes as a result of early cancer findings, leading to earlier intervention. Unfortunately, the medical and scientific consensus on the question of benefit to long-term survival is likely decades away. It may take 20 to 30 years of longitudinal data to determine whether the early detection of asymptomatic cancers through full-body MRI leads to meaningful improvements in survival for the general population.
It is important to note that the lack of published evidence does not imply a lack of benefit—rather, the degree of benefit is not yet known.
Over the next 30 years, as screening technologies proliferate (including genetics, circulating tumour cells, blood tests, and AI-driven biomarkers), we face a growing paradox: we may win the battle of early detection but lose the ability to evaluate cancer’s natural course of disease. This undermines the foundation of our scientific understanding, which relies on observing a control group (unscreened, untreated) to determine whether early detection genuinely improves survival.
As a result, the decision to screen becomes deeply personal. And, respectfully, some may choose not to wait for what may never eventuate.
Future Direction
The evolution of full-body MRI from a research curiosity to a clinical mainstay is a testament to decades of innovation. On the horizon, full-body MRI is expected to evolve further with the development of whole-body quantification applications, artificial intelligence-driven image resolution, and automated lesion detection. These innovations aim to enhance diagnostic precision and consistency across patient populations.
A growing area of interest for the team at Whole Body MRI™ is the integration of imaging-based biomarkers—quantifiable markers that can indicate early pathological changes even before symptoms arise.
Learn more about our technology, view our packages, or book an appointment via our Partner Clinic.
Disclaimer
The information is shared solely for educational and informational purposes and is not intended as medical advice. While these approaches may support healthy brain aging, individual needs and responses vary. Always consult with a qualified healthcare provider before beginning any new treatment, supplement, or health regimen. This content is not a substitute for professional medical evaluation, diagnosis, or care.
References
-
Roguin, A. (2004). Nikola Tesla: The man behind the magnetic field unit. Journal of Magnetic Resonance Imaging, 19(3), 369–374. https://doi.org/10.1002/jmri.20002
-
Giunta, C. J., & Mainz, V. V. (2020). Discovery of nuclear magnetic resonance: Rabi, Purcell, and Bloch. In E. T. Strom & V. V. Mainz (Eds.), Pioneers of Magnetic Resonance (ACS Symposium Series No. 1349). American Chemical Society. https://doi.org/10.1021/bk-2020-1349.ch001
-
Takahara, T., Imai, Y., Yamashita, T., Yasuda, S., Nasu, S., & Van Cauteren, M. (2004). Diffusion weighted whole body imaging with background body signal suppression (DWIBS): Technical improvement using free breathing, STIR and high resolution 3D display. Radiation Medicine, 22(4), 275–282.
-
Sodickson, D. K., Griswold, M. A., & Jakob, P. M. (1999). SMASH imaging. Magnetic Resonance Imaging Clinics of North America, 7(2), 237–viii.
-
Machado Medeiros, T., Altmayer, S., Watte, G., et al. (2020). 18F-FDG PET/CT and whole-body MRI diagnostic performance in M staging for non-small cell lung cancer: A systematic review and meta-analysis. European Radiology, 30(7), 3641–3649. https://doi.org/10.1007/s00330-020-06703-1
-
Mulé, S., Reizine, E., Blanc-Durand, P., et al. (2020). Whole-Body Functional MRI and PET/MRI in Multiple Myeloma. Cancers (Basel), 12(11), 3155. https://doi.org/10.3390/cancers12113155
-
Fernandes, M. C., Yildirim, O., Woo, S., Vargas, H. A., & Hricak, H. (2022). The role of MRI in prostate cancer: Current and future directions. Magnetic Resonance Materials in Physics, Biology and Medicine (MAGMA), 35(4), 503–521. https://doi.org/10.1007/s10334-022-01006-6
-
Bhaludin, B. N., Tunariu, N., Koh, D. M., et al. (2022). A review on the added value of whole-body MRI in metastatic lobular breast cancer. European Radiology, 32(9), 6514–6525. https://doi.org/10.1007/s00330-022-08714-6
-
Koh, D. M., Blackledge, M., Padhani, A. R., et al. (2012). Whole-body diffusion-weighted MRI: Tips, tricks, and pitfalls. AJR American Journal of Roentgenology, 199(2), 252–262. https://doi.org/10.2214/AJR.11.7866
-
Petralia, G., Zugni, F., Summers, P. E., et al. (2021). Whole-body magnetic resonance imaging (WB-MRI) for cancer screening: Recommendations for use. Radiologia Medica, 126(11), 1434–1450. https://doi.org/10.1007/s11547-021-01392-2
-
Kwee, R. M., & Kwee, T. C. (2019). Whole-body MRI for preventive health screening: A systematic review of the literature. Journal of Magnetic Resonance Imaging, 50(5), 1489–1503. https://doi.org/10.1002/jmri.26736
-
Parillo, M., & Mallio, C. A. (2025). The Whole-Body MRI Reporting and Data System Guidelines for Prostate Cancer (MET-RADS-P), Multiple Myeloma (MY-RADS), and Cancer Screening (ONCO-RADS). Cancers (Basel), 17(2), 275. https://doi.org/10.3390/cancers17020275
-
Kennedy, B. (2022). Whole-body DWI at 3T with inline geometric distortion correction and broadband RF inversion. Presented at the ISMRM/ISMRT Annual Meeting, London, UK.
About the Author
Dr. A. Forbes (PhD) is a medical and science writer with significant clinical and laboratory-based research experience with a particular interest in advancing early detection and oncology treatments. She works with Whole Body MRI Pty Ltd and MBR Health (formerly Mermaid Beach Radiology) to facilitate Investigator-Initiated research evaluating novel-imaging based-biomarkers of disease.